ALTIVAR
58 Keypad Display VVDED397047US R8/01
Chapter 2 — Menus 08/01
70
© 1998–2001 Schneider Electric All Rights Reserved
Figure 19: Brake Logic Timing Diagram
Parameters accessible in the 2—Adjust menu:
• brake release frequency (brL)
• brake release current (Ibr)
• brake release time (brt)
• brake engage frequency (bEn)
• brake engage time (bEt)
Recommendations for configuring the Brake Logic control parameters:
• Brake release frequency (brL):
Set the brake release frequency to the value of the nominal slip (g)
multiplied by the nominal frequency (FS) in Hz.
brL = g x FS
g = nominal motor slip
FS = nominal motor frequency (indicated on the motor nameplate)
Example Calculation: nominal slip (g) = (Ns – Nr) / Ns
Ns = synchronous speed in rpm
Nr = nominal speed at nominal torque in rpm, use the speed
indicated on the motor nameplate
Referenc
Brake State
R2 Relay
Motor Current
Motor Frequency
bEn
Ibr
brL
brtT bEt
Motor Speed
Increasing or Decreasing
1
0
1
0
1
0
T = non-adjustable delay