VVDED397047US R8/01 ALTIVAR
58 Keypad Display
08/01 Chapter 1 Overview
© 19982001 Schneider Electric All Rights Reserved
17
ACCESS LEVELS
Figure 5: Rear View of Keypad Display
The position of the access locking switch on the back of the programming
keypad display allows three levels of access to the menus. Access to the
menus can also be prevented by using an access code (see the 7File
menu on page 79).
Locked Position Display Mode: use when the motor is running
to prevent modifications to the drive controller programming.
You can select the dialog language in the LANGUAGE menu.
You can display the macro-configuration or the pre-programmed
values for the selected application in the MACRO-CONFIG menu.
You can display the voltage and power rating of your drive controller in
the IDENTIFICATION menu.
You can display the electrical values, the operational status, or fault in
the 1DISPLAY menu.
Partial Lock Position Display and Adjustment Modes: this
level is used during startup for access to basic setup parameters.
You can do everything listed above.
You can use the 2ADJUST menu to adjust parameters which are
accessible when the motor is running.
Connector (9-pin SUB-D male):
- for direct connection to the drive controller
- for remote mounting, the keypad display can be
connected using a cable provided in kit
VW3A58103
Switch for access locking:
- locked : display mode only, adjustment and
position configuration parameters not
accessible
- partial : display mode and adjustment
lock parameters accessible
position
- total : display mode, adjustment and
unlock configuration parameters accessible
position