ALTIVAR
58 Keypad Display VVDED397047US R8/01
Appendix A—Drive Controller Configuration 08/01
102
© 1998–2001 Schneider Electric All Rights Reserved
Menu 4 – CONTROL Menu (page 45)
Parameter Code Factory Setting
Terminal Strip Con
Two Wire 2W
Three Wire 3W
Type 2 Wire
No Transition
Low to High Trans.
Forward Input Pri.
Inhibit Reverse
Low Speed Magmt
Linear LSP to HSP
Pedestal Start
Deadband Start
AI2 Min. Ref. -mA
AI2 Max. Ref. -mA
Min. Val. AO * mA
Max. Val. AO * mA
Reference Memory
No memory
Run Com. removed
Power removed
Keypad Com.
Stop Priority
Drive Address
Bd Rate RS485
Reset Counters
tCC
2 W
3 W
tCt
LEL
trn
PFW
rIn
bSP
no
BLS
BnS
CrL
CrH
AOL
AOH
Str
no
RAM
EEP
LCC
PSt
Add
tbr
rpr
2 W
LEL
no
no
4 mA
20 mA
0 mA
20 mA
no
no
yes
0
Menu 5– I/O Menu (page 51)
Parameter Code Factory Setting
LI2 Assign
LI3 Assign
LI4 Assign
LI5 Assign *
LI6 Assign *
Not assigned
RV: Reverse
Switch Ramp2
JOG
+SP: +Speed
-Speed
2 preset Sp
4 preset SP
8 preset Sp
Freewheel Stop
DC inject
Fast stop
Multi. Motor
TorqueLim2
Forced Local
Fault Reset
Auto/manu
Auto-tune
PID Auto/Man
PID 2 Preset
PID 4 Preset
Torque Limit by AI
AI2 Assign
AI3 Assign *
Not assigned
Speed ref 2
Summed ref.
PID regulator
PID Manual Ref.*
Tacho feedback *
Therm. Sensor *
Torque Limit *
Encoder feedback *
LI2
LI3
LI4
LI5
LI6
no
RV
RP2
JOG
SP
-SP
PS2
PS4
PS8
nSt
OCI
FSt
CHP
tL2
FLO
rSt
rFC
Atn
PAU
Pr2
Pr4
tLA
AI2
AI3
no
Fr2
SAI
PIF
PIM
SFb
PtC
AtL
rGI
R2 Assign / LO assign
Not assigned
Drive running
Output contactor
Freq reference attain.
HSP attained
Current level attained
Reference Freq. Attain.
Motor thermal lvl (Attain)
Brake logic
4-20mA loss
F2 attained
AO Assign *
Not assigned *
Motor current *
Motor frequency *
Output ramp *
Motor torque *
Signed Torque *
Signed Ramp *
PID Reference *
PID Feedback *
PID Error *
PID Integral *
Motor Power *
Motor Thermal *
Drive Thermal *
r2 / LO
no
rUn
OCC
FtA
FLA
CtA
SrA
tSA
bLC
APL
F2A
AO
no
OCr
OFr
OrP
trq
Stq
OrS
OPS
OPF
OPE
OPI
OPr
tHr
tHd
no
Menu 6 – FAULT Menu (page 75)
Parameter Code Factory Setting
Auto Restart
Reset Type
Partial Reset
Total Reset
Output Phase Loss
Input Phase Loss
Thermal Protection
No motor protection
Self Cooled motor
Force Cooled motor
Loss Follower
Immediate Fault
Restart on Signal Return
Stop and Fault
Run at Preset Speed
Catch On Fly
Controlled Stop
Phase loss drive trip
Regen w/dc Bus
Follow dc bus
Ramp not Followed *
Atr
rSt
rSP
rSG
OPL
IPL
tHt
no
ACL
FCL
LFL
yes
Stt
LSF
LFF
FLr
StP
no
nnS
FrP
Sdd
no
RSP
yes
yes
ACL
no
no
no
no
Menu 7 – FILES Menu (page 79)
Parameter Code Factory Setting
File 1 State
File 2 State
File 3 State
File 4 State
Operation Type
No Operation Req.
Save Configuration
Transfer File to Drive
Return to Factory Set
File Number
Password
F1S
F2S
F3S
F4S
FOt
no
Str
rEC
InI
FLn
Cod
FREE
FREE
FREE
FREE
no
0000
Menu 5– I/O Menu (page 51) (Continued)
Parameter Code Factory Setting
* Requires addition of I/O option card VW3A58201U (analog) or VW3A58202U (digital)