VVDED397047US R8/01 ALTIVAR
58 Keypad Display
08/01 Chapter 2 — Menus
© 1998–2001 Schneider Electric All Rights Reserved
33
Preset Sp.2- Hz
SP2
Second preset speed LSP to HSP 10 Hz
Preset Sp.3- Hz
SP3
Third preset speed LSP to HSP 15 Hz
Preset Sp.4- Hz ★
SP4
Fourth preset speed LSP to HSP 20 Hz
Preset Sp.5- Hz ★
SP5
Fifth preset speed LSP to HSP 25 Hz
Preset Sp.6- Hz ★
SP6
Sixth preset speed LSP to HSP 30 Hz
Preset Sp.7- Hz ★
SP7
Seventh preset speed LSP to HSP 35 Hz
Curr.Lev.Att: A ★
Ctd
Current threshold above which the
logic output or the relay changes to 1
0.25 to 1.36
of I
n
[1]
1.36 of
I
n
[1]
Table 7: 2—Additional Adjustment Parameters with Material
Handling Macro-Configuration
Parameter Code Description
Adjustment
Range
Factory
Setting
[1]
I
n
= drive controller constant torque output current rating shown on the drive
controller nameplate.
★ Parameters appear if an I/O extension card is installed.
Menu