VVDED397047US R8/01 ALTIVAR
58 Keypad Display
08/01 Chapter 2 — Menus
© 1998–2001 Schneider Electric All Rights Reserved
45
4—CONTROL MENU
The Control Menu is accessible when the access locking switch is in the
position. The parameters can only be modified when the motor is
stopped.
Table 12: 4—Control Menu: Keypad Display or 2- and 3-Wire
Control
Parameter Code Description
Adjustment
Range
Factory
Setting
TermStripCon.
tCC
Configuration of the terminal strip
command: 2- or 3-wire control.
2W - 3W 2W
Note: modification of this parameter requires two confirmations
since it causes a reassignment of the logic inputs. Shown below
are the LI assignments when 3-wire control is selected. When
2-wire control is selected, the assignments are those shown in
Table 3 on page 22. In 3-wire control, LI1 and LI2 cannot be
reassigned.
I/O Material Handling General Use Variable Torque
LI1 STOP STOP STOP
LI2 Run forward Run forward Run forward
LI3 Run reverse Run reverse Run reverse
LI4 2 Preset speeds Jog Reference switching
LI5★ 4 Preset speeds Freewheel stop Injection braking
LI6★ 8 Preset speeds Clear faults Freewheel stop
Selecting 3-wire control inhibits the automatic restart
function.
3-wire control wiring example:
★ These I/O can be accessed if an I/O extension card has been installed.
Menu
4
24 V LI1 LI2 LIx
ATV58 Terminal strip
LI1: Stop
LI2: Forward
LIx: Reverse
Comentarios a estos manuales