Schneider Electric ALTIVAR 58 TRX Guía de instalación Pagina 76

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 126
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 75
© 1998–2003 Schneider Electric All Rights Reserved
Chapter 2—Menus VVDED397047USR6/03
5—I/O Menu 06/2003
76
Assignment of AI2 and AI3
Summing Speed Reference: The frequency setpoints given by AI2
and AI3 can be summed with AI1.
Speed Regulation with Tachogenerator: (Assignment on AI3 only
with an I/O extension card, VW3A58201U)
An external divider bridge is required to adapt the voltage of the
tachogenerator. The maximum voltage must be between 5 and 9 V. A
precise setting is then obtained by setting the dtS parameter available
in the 2—Adjust menu.
PTC Probe Processing: (only with an I/O extension card using the
analog input). Used for direct thermal protection of the motor by
connecting the PTC probes in the motor windings to analog input AI3.
Preset
setpoints
Pr2, Pr4
PI2, PI3
0–100% of
process
maximum
(HSP)
Logic inputs can also be used to provide programmable setpoints.
Two or four preset setpoints require the use of one or two logic
inputs respectively.
For example, the factory settings of PI2 and PI3 are 30% and 60%
respectively and if HSP is 60 Hz, PI2 setpoint will be 18 Hz and PI3
setpoint will be 36 Hz.
PI Inversion PIC Yes/No
PI inversion permits an inverted, or
reverse-acting, response to the
PI
setpoint signal. If PIC = No, the motor speed increases when the
error is positive. If PIC = Yes, the motor speed decreases when the
error is positive.
PI proportional
gain
rPG 0.01–100
PI regulator proportional gain adjusts the scaling of the
PI setpoint
signal.
PI integral gain rlG 0.01–100 s PI regulator integral gain adjustment.
Time-constant
feedback filter
PSP 0–10 s
PSP can be used to dampen the feedback signal. If PSP is set to
zero, the ACC and dEC ramps are active. If PSP is > 0, the
AC2/dE2 ramps are active. Adjustment of AC2/dE2 can be used to
refine the response of the PI loop. The dEC ramp is always used on
stopping.
PI feedback
scaling
FbS 1.0–100
PI feedback scaling allows adjustment of the maximum value of the
PI feedback signal so that it corresponds to the maximum value of
the PI regulator speed reference.
Table 20: Definition of PI Regulator Inputs and Adjustments (continued)
Input Code Range Description
2 preset setpoints 4 preset setpoints
Assign: LIx to Pr2 Assign: LIx to Pr2, then LIy to Pr4
LIx Reference LIy LIx Reference
0
1
Analog reference
Process max. (HSP)
0
0
0
1
Analog reference
PI2 (adjustable)
1
1
0
1
PI3 (adjustable)
Process max. (HSP)
Vista de pagina 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 ... 125 126