Schneider Electric Xantrex XW Guía de instalación Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 62
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
Mounting
975-0540-01-01 Revision B 2–7
This guide is for use by qualified personnel only.
Mounting the Charge Controller
The charge controller must be vertically mounted to the wall using three ¼-inch ×
½-inch (6.35 mm × 12.5 mm) pan head screws. It can also be mounted on the
side of the PDP
(the hardware is provided with the
charge controller
).
To mount the charge controller (see Figure 2-6 on page 2–8):
1. Remove the wiring compartment cover (see page 2–5).
2. Mark the location of the keyhole slot on the wall.
3. Secure the top mounting screw in the location marked, but leave the screw
head backed out approximately ¼ inch (6 mm).
4. Place the charge controller onto the screw and pull it down into the keyhole
slot.
5. Insert two screws in the two mounting holes provided to secure the charge
controller to the wall.
Figure 2-5 Dimensions and knockout locations
764.0
(30.0)
220.5
(8.68)
44.0
(1.73) KNOCKOUT
28.2
(1.11)/
22.2(0.87)
DUAL KNOCKOUT
35.0 (1.38)/
28.2 (1.11)
DUAL KNOCKOUT 3PL
108.4 (4.27)
61.9 (2.44) 673.4 (26.5)
219.7 (8.65)
Keyhole slot for wall mounting
All measurements in mm (in.)