Mounting
975-0540-01-01 Revision B 2–5
This guide is for use by qualified personnel only.
Removing the Wiring Compartment Cover
Before mounting, remove the wiring compartment cover to access the mounting
holes and the wiring terminals. The wiring compartment cover is secured with
two screws on the front of the charge controller (see Figure 2-2).
The wiring compartment (see Figure 2-3) contains a flexible Lexan™ barrier used
to segregate battery and PV wire routing. In some instances, you must
manipulate this barrier to provide a passage for battery or PV cables running
through the wiring compartment. In this scenario, you must take care to avoid
intermingling of PV and battery wires.
HAZARD OF ELECTRIC SHOCK AND ENERGY
Before removing the wiring compartment cover, make sure all sources of
electricity have been disconnected for at least two minutes. Before energizing
the charge controller, make sure the wiring compartment cover has been
replaced with all fasteners.
Failure to follow these instructions will result in death or serious injury.
Figure 2-2 Removing the wiring compartment cover
Remove two screws to
access the wiring terminals.
Figure 2-3 Wiring compartment with Lexan barrier