AS-i Bus
TELEFAST SB2 Intelligent Interfaces
37
03/00
© 2000 Schneider Electric All Rights Reserved
Electrical Durability (in millions of operating cycles, according to IEC 947-5-1)
Electrical durability of electromechanical relays on the ABE8R44SB1, ABE8R44SF10, and ABE8R04S010 interfaces
DC12 curves (1) DC13 curves (2)
AC12 curves (3) AC14 curves (4) AC15 curves (5)
(1) DC12: control of resistive loads and solid state loads optically isolated, I/R ≤ 1 ms.
(2) DC13: control of electromagnets, L/R ≤ 2 x (Ue x Ie) in ms, Ue: rated operating voltage, Ie: rated operating current (with protective diode across load, DC12 curves
must be used with a coefficient of 0.9 applied to the number in millions of operating cycles).
(3) AC12: control of resistive loads and solid state loads optically isolated, power factor (pf) ≥ 0.9.
(4) AC14: control of small electromagnetic loads from electromagnets ≤72 VA, make: pf = 0.3, break: pf = 0.3.
(5) AC15: control of electromagnetic loads from electromagnets > 72 VA, make: pf = 0.7, break: pf = 0.4.
General System Environment
Product Certifications AS-i
Enclosure Rating Conforming to IEC 529 IP 2X
Shock Resistance Conforming to IEC 68-2-27
11 ms (semi-sinusoidal)
15 g (acceleration)
Vibration Resistance
5 to 13.2 Hz ± 1 mm
13.2 to 100 Hz- 0.7 gn
Resistance to Electrostatic Discharges Conforming to IEC 1000-4-2 Level 3
Resistance to Radiated Fields Conforming to IEC 1000-4-3 Level 3
Resistance to Transients Conforming to IEC 1000-4-4 Level 3
Surge Withstand Conforming to IEC 1000-4-5 1 kV at 2 Ohms (differential mode), 2 kV at 12 Ohms (common mode)
Ambient Air Temperature
Operation, conforming to IEC 1131-2 -23 °F to +140 °F (-5 °C to +60 °C)
Storage, conforming to IEC 1131-2 -40 °F to +176 °F (-40 °C to +80 °C)
Insulation Voltage (for 1 minute) Terminals/fixing rails 2 kV
Installation Category Conforming to IEC 664 II
Degree of Pollution Conforming to IEC 664 2
Mounting Standard profiles
On backplate: 15 mm DIN rail or using ABEACC01
On chassis: 15 mm and 7.5 mm DIN rails
Suitable Cable Sections
1 conductor 2 conductors
Flexible cable without cable end
0.14 to 2.5 mm
2
26 to 14 AWG
–
–
Flexible cable with cable end
0.14 to 1.5 mm
2
26 to 16 AWG
0.14 to 0.75 mm
2
26 to 18 AWG
Solid cable
0.14 to 2.5 mm
2
26 to 14 AWG
0.14 to 1.5 mm
2
26 to 16 AWG
Tightening Torque With 3.5 mm screwdriver 5.3 lb-in (0.6 N•m) 5.3 lb-in (0.6 N•m)
0 1.5120.5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
24V
48V
0.1 0.3 0.5 0.7 0.9 10.2 0.4 0.6 0.8
0.0
1.4
1.2
1.0
0.8
0.6
0.4
0.2
L/R = 10ms 24V
L/R = 60ms 24V
0 0.5 1.5 2.5 3.5 4.51.0 2.0 3.0 4.0 5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
24V
48V
110V
220V
0 0.2 0.6 1.0 1.4 1.80.4 0.8 1.2 1.6 2
0.0
0.5
1.0
1.5
2.0
2.5
24V
48V
110V
220V
0.5 0.90.7 1.31.1 1.71.5 1.9
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
220V
110V
Comentarios a estos manuales