865-1000 (Xantrex XW6048-NA) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
865-1000.01_03_00.BN0012 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2
865-1000.01_05_00.BN0011 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2
865-1000.01_07_00.BN0003 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4
865-1005 (Xantrex XW4548-NA) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5
865-1005.01_04_00.BN0015 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -5
865-1005.01_07_00.BN0003 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -6
865-1010 (Xantrex XW4024-NA) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8
865-1010.01_04_00.BN0002 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -8
865-1010.01_07_00.BN0003 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -9
865-1035 (Xantrex XW6048-EU)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
865-1035.01_07_00.BN0005 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
865-1040 (Xantrex XW4548-EU)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14
865-1040.01_07_00.BN0006 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14
865-1045 (Xantrex XW4024-EU)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16
865-1045.01_07_00.BN0005 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16
865-1030 (Xantrex XW MPPT Charge Controller) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20
865-1030.01_05_00.BN0006 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20
Schneider Electric Xantrex ™ XW
Software Release Notes
975-0604-01-01
Revision A
NOTICE
When updating firmware for a multi-unit system, make sure all units are updated before operation.
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - Software Release Notes

865-1000 (Xantrex XW6048-NA) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2865-1000.01_03_00.BN0012

Pagina 2 - 865-1000 (Xantrex XW6048-NA)

Software Release Notes10 975-0604-01-01 Revision A4. Updated grid/gen entry/exit/regulation voltage offsets in respect of grid/gen support voltage.5.

Pagina 3

Software Release Notes975-0604-01-01 Revision A 1110. Changed the fault-set hysteresis to 0V for F48 (DC under voltage fault) to prevent premature fau

Pagina 4 - 865-1000.01_07_00.BN0003

Software Release Notes12 975-0604-01-01 Revision A5. Fixed problem where system would lock up after multiple adjustments of support amps from 0 to 10

Pagina 5 - 865-1005 (Xantrex XW4548-NA)

Software Release Notes975-0604-01-01 Revision A 13e) Vbulk and Vabs settings are now totally independent from each other on SCP.f) Minimum charge perc

Pagina 6 - 865-1005.01_07_00.BN0003

Software Release Notes14 975-0604-01-01 Revision A31. Changed "FREQ" cmd so that it now accepts decimal frequency settings such as "55.

Pagina 7

Software Release Notes975-0604-01-01 Revision A 159. Updated grid/gen entry/exit/regulation voltage offsets in respect of grid/gen support voltage.10.

Pagina 8 - 865-1010 (Xantrex XW4024-NA)

Software Release Notes16 975-0604-01-01 Revision A16. Improved charge voltage regulation in a multiunit installation where more than one unit is charg

Pagina 9 - 865-1010.01_07_00.BN0003

Software Release Notes975-0604-01-01 Revision A 173. Changed frequency hysteresis from 2hz to 0.5hz4. Changed minimum breaker size to 3A.5. Implemente

Pagina 10

Software Release Notes18 975-0604-01-01 Revision Ad) 0Ahr battery capacity is deemed that there is no absorption exit current criteria and absorption

Pagina 11 - 865-1035 (Xantrex XW6048-EU)

Software Release Notes975-0604-01-01 Revision A 1929. Changed "FREQ" cmd so that it now accepts decimal frequency settings such as "55.

Pagina 12

Software Release Notes2 975-0604-01-01 Revision A865-1000 (Xantrex XW6048-NA)865-1000.01_03_00.BN0012Build Range: 865-1000.01_00_00.BN0028 — 865-1000.

Pagina 13

Software Release Notes20 975-0604-01-01 Revision A865-1030 (Xantrex XW MPPT Charge Controller)865-1030.01_05_00.BN00061. The charge algorithm was modi

Pagina 14 - 865-1040 (Xantrex XW4548-EU)

Software Release Notes975-0604-01-01 Revision A 212. Improvements were made to the Xantrex Xanbus library to make the device more robust on the CAN ne

Pagina 15

Software Release Notes22 975-0604-01-01 Revision ASchneider Electric, the Schneider Electric logo, Xanbus and Xantrex are trademarks or registered tra

Pagina 16 - 865-1045 (Xantrex XW4024-EU)

Software Release Notes975-0604-01-01 Revision A 33. Changed frequency hysteresis from 2hz to 0.5hz.4. Changed minimum breaker size to 3A.5. Implemente

Pagina 17

Software Release Notes4 975-0604-01-01 Revision A12. Changed battery temperature compensation during charge from 10°C-40°C to 0°C-50°C13. Implemented

Pagina 18

Software Release Notes975-0604-01-01 Revision A 5865-1005 (Xantrex XW4548-NA)865-1005.01_04_00.BN0015Build number range: 1.0.0BN10 — 1.4.0BN15Time ran

Pagina 19

Software Release Notes6 975-0604-01-01 Revision A13. Fixed incorrect power calculation for AC Gen L1.14. Disabled SINEGEN sync functionality on hibern

Pagina 20 - 865-1030.01_05_00.BN0006

Software Release Notes975-0604-01-01 Revision A 73. Implemented new charge algorithm. The differences from the previous implementation are:a) Bulk exi

Pagina 21

Software Release Notes8 975-0604-01-01 Revision A16. Changed AC coupling frequency push limits down to -5Hz.17. Made phase_error and period_error limi

Pagina 22 - 22 975-0604-01-01 Revision A

Software Release Notes975-0604-01-01 Revision A 910. Changed warning 70 into fault 70 ( phase configuration fault).11. Eliminated fault, warning and e