Configuring an M1 CPU with Modsoft
870 USE 101 10 V.2 215
Changing the Range of Discrete and Register References
Introduction This section provides guidelines and a procedure for changing the range of discrete
(0
x
and 1
x
) and register (3
x
and 4
x
) references.
Guidelines When you change the range of discrete and register references, follow these
guidelines:
l Adjust the range of discretes in increments of 16. Sixteen discretes consume
one word.
l Adjust the range of registers in increments of 1. Each register consumes one
word.
l The total number of register and discrete references cannot exceed 3k words.
l A minimum configuration of 16 0
x
discretes, 16 1
x
discretes, one 3
x
register,
and one 4
x
register is required.