Schneider Electric PowerLogic PM5300 Series Guía de usuario Pagina 1

Busca en linea o descarga Guía de usuario para De medición, control y control Schneider Electric PowerLogic PM5300 Series. Schneider Electric PowerLogic PM5300 Series User guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - Energy Meter

PQSPowerLogic™ PM5300 Series Power and Energy MeterUser GuideEAV15107 - EN0304/2014

Pagina 2

PowerLogic™ PM5300 user guide Chapter 1—Introduction© 2014 Schneider Electric All Rights Reserved10

Pagina 3 - Safety Information

100 © 2014 Schneider Electric All Rights ReservedChapter 13—Meter resets PowerLogic™ PM5300 series user guide5. Press Yes to confirm the reset or No

Pagina 4

PowerLogic™ PM5300 series user guide Chapter 13—Meter resets© 2014 Schneider Electric All Rights Reserved 101PowerOver kWSelect which alarm counter

Pagina 5

102 © 2014 Schneider Electric All Rights ReservedChapter 13—Meter resets PowerLogic™ PM5300 series user guide

Pagina 6

PowerLogic™ PM5300 User Guide Chapter 14—Maintenance and Upgrades© 2014 Schneider Electric All Rights Reserved103Chapter 14—Maintenance and UpgradesA

Pagina 7

PowerLogic™ PM5300 series user guide Chapter 14—Maintenance and Upgrades© 2014 Schneider Electric All Rights Reserved104Additional Meter Status Info

Pagina 8

PowerLogic™ PM5300 User Guide Chapter 14—Maintenance and Upgrades© 2014 Schneider Electric All Rights Reserved105TroubleshootingThe information in Ta

Pagina 9 - Chapter 1—Introduction

PowerLogic™ PM5300 series user guide Chapter 14—Maintenance and Upgrades© 2014 Schneider Electric All Rights Reserved106The power meter does not con

Pagina 10

© 2014 Schneider Electric All Rights Reserved 107Chapter 15—MID ComplianceThis section applies only to PM5331/PM5341(referred to in the section as the

Pagina 11 - Chapter 2—Safety Precautions

108 © 2014 Schneider Electric All Rights ReservedChapter 15—MID Compliance PowerLogic™ PM5300 seriesSafety precautionsInstallation, wiring, testing an

Pagina 12

PowerLogic™ PM5300 series Chapter 15—MID Compliance© 2014 Schneider Electric All Rights Reserved 109Related topics• See “Meter mounting” on page 18 a

Pagina 13 - Chapter 3—Hardware Reference

PowerLogic™ PM5300 series user guide Chapter 2—Safety Precautions© 2014 Schneider Electric All Rights Reserved11Chapter 2—Safety PrecautionsBefore Yo

Pagina 14

110 © 2014 Schneider Electric All Rights ReservedChapter 15—MID Compliance PowerLogic™ PM5300 seriesRelated topics• See “Front panel display and meter

Pagina 15 - Technical Specifications

PowerLogic™ PM5300 series Chapter 15—MID Compliance© 2014 Schneider Electric All Rights Reserved 111Setting up the PM5331/PM5341You must configure al

Pagina 16

112 © 2014 Schneider Electric All Rights ReservedChapter 15—MID Compliance PowerLogic™ PM5300 seriesLocking or unlocking the meterAfter you initialize

Pagina 17 - Dimension

PowerLogic™ PM5300 series user guide Glossary© 2014 Schneider Electric All Rights Reserved113GlossaryTermsaccumulated energy—energy accumulates as e

Pagina 18 - Meter mounting

PowerLogic™ PM5300 series user guide Glossary© 2014 Schneider Electric All Rights Reserved114partial interval demand—equal to energy accumulated thu

Pagina 19 - Meter wiring

PowerLogic™ PM5300 series user guide Glossary© 2014 Schneider Electric All Rights Reserved115AbbreviationsA—AmpereAmps—AmperesComms—CommunicationsCP

Pagina 20 - $$120$

PowerLogic™ PM5300 series user guide Glossary© 2014 Schneider Electric All Rights Reserved116Pulse—Pulse output modePwr—PowerQ—Reactive powerQd—Reac

Pagina 21 - Recommended cables

PowerLogic™ PM5300 series user guide Index© 2014 Schneider Electric All Rights Reserved117Aadvanced setup 41alarmicon 66LED 66alarm LED 63alarm Log

Pagina 22 - Wiring Diagrams

PowerLogic™ PM5300 series user guide Index© 2014 Schneider Electric All Rights Reserved118

Pagina 24 - Meter setting

PowerLogic™ PM5300 series user guide Chapter 2—Safety Precautions© 2014 Schneider Electric All Rights Reserved12• Reorient or relocate the receiving

Pagina 25 - Current input protection

EAV15107 - EN03 © 2014 Schneider Electric. All rights reserved. 04/2014Schneider Electric35, rue Joseph MonierCS 30323F - 92506 Rueil Malmaison Cedexw

Pagina 26 - Communications

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 13Chapter 3—Hardware ReferenceThis sec

Pagina 27 - RS-485 network configuration

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved14FrequencyReal, reactive, and apparen

Pagina 28 - SWITCH / HUB

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 15Technical SpecificationsElectrical C

Pagina 29 - Relay outputs

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved16Meter constantfrom 1 to 9,999,999 pul

Pagina 30 - (70)(71)(73)(74)

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 17Before you beginCarefully read and f

Pagina 31 - LED indicators

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved18Meter mountingThis section describes

Pagina 32 - Meter screen menus

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 194. Push the middle of the clip assem

Pagina 34 - Front panel meter setup

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved20Serial No. Description SpecificationR

Pagina 35 - Meter Basic

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 21Recommended cablesCommunication Make

Pagina 36 - Setup Meter

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved22Wiring Diagrams1PH1PH2WLN 1PH2WLL 1PH

Pagina 37

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 23NOTE:• Clearly label the device’s di

Pagina 38 - HMI settings

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved24Power system setup parametersPower sy

Pagina 39 - Setting up regional settings

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 25Voltage and current input wiringFor

Pagina 40 - Lost password

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved26Balanced system considerationsIn situ

Pagina 41 - Advanced setup

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 27communicate with the slave devices,

Pagina 42 - Related topics

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved28Related topics• To configure RS-485 c

Pagina 43 - Demand setup

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved 29Related topics• See “Digital output

Pagina 44 - Remote Meter Setup

Safety InformationImportant InformationRead these instructions carefully and look at the equipment to become familiar with the device before trying to

Pagina 45 - Chapter 5—Viewing Meter Data

PowerLogic™ PM5300 series user guide Chapter 3—Hardware Reference© 2014 Schneider Electric All Rights Reserved30* The overcurrent protective device m

Pagina 46

PowerLogic™ PM5300 series user guide Chapter 4—Front panel display and meter setup© 2014 Schneider Electric All Rights Reserved 31Chapter 4—Front pa

Pagina 47

32 © 2014 Schneider Electric All Rights ReservedChapter 4—Front panel display and meter setup PowerLogic™ PM5300 series user guideRelated topics• See

Pagina 48

PowerLogic™ PM5300 series user guide Chapter 4—Front panel display and meter setup© 2014 Schneider Electric All Rights Reserved 33Menu treeThis summ

Pagina 49 - (40) (42) (57) (56)

34 © 2014 Schneider Electric All Rights ReservedChapter 4—Front panel display and meter setup PowerLogic™ PM5300 series user guideMeter setup screen

Pagina 50 - Status input setup

PowerLogic™ PM5300 series user guide Chapter 4—Front panel display and meter setup© 2014 Schneider Electric All Rights Reserved 351. Navigate to Mai

Pagina 51

36 © 2014 Schneider Electric All Rights ReservedChapter 4—Front panel display and meter setup PowerLogic™ PM5300 series user guideRelated topics• See

Pagina 52 - Digital output applications

PowerLogic™ PM5300 series user guide Chapter 4—Front panel display and meter setup© 2014 Schneider Electric All Rights Reserved 377. Press to exit

Pagina 53 - Parameter Values Description

38 © 2014 Schneider Electric All Rights ReservedChapter 4—Front panel display and meter setup PowerLogic™ PM5300 series user guide7. Press to exit.

Pagina 54

PowerLogic™ PM5300 series user guide Chapter 4—Front panel display and meter setup© 2014 Schneider Electric All Rights Reserved 397. Press to exit

Pagina 56

40 © 2014 Schneider Electric All Rights ReservedChapter 4—Front panel display and meter setup PowerLogic™ PM5300 series user guideprotected prevents

Pagina 57 - Relay output applications

PowerLogic™ PM5300 series user guide Chapter 4—Front panel display and meter setup© 2014 Schneider Electric All Rights Reserved 41Setting the clockT

Pagina 58

42 © 2014 Schneider Electric All Rights ReservedChapter 4—Front panel display and meter setup PowerLogic™ PM5300 series user guide3. Navigate to Mete

Pagina 59

PowerLogic™ PM5300 series user guide Chapter 4—Front panel display and meter setup© 2014 Schneider Electric All Rights Reserved 43Related topics• Se

Pagina 60

44 © 2014 Schneider Electric All Rights ReservedChapter 4—Front panel display and meter setup PowerLogic™ PM5300 series user guide8. Press Yes to sav

Pagina 61 - ION Setup

PowerLogic™ PM5300 series user guide Chapter 5—Viewing Meter Data© 2014 Schneider Electric All Rights Reserved 45Chapter 5—Viewing Meter DataYou ca

Pagina 62

46 © 2014 Schneider Electric All Rights ReservedChapter 5—Viewing Meter Data PowerLogic™ PM5300 series user guideRelated topics• See “Current demand”

Pagina 63 - Chapter 7—Alarms

PowerLogic™ PM5300 series user guide Chapter 5—Viewing Meter Data© 2014 Schneider Electric All Rights Reserved 47Related topics• See “Power quality”

Pagina 64 - Dropout Setpoint (magnitude)

48 © 2014 Schneider Electric All Rights ReservedChapter 5—Viewing Meter Data PowerLogic™ PM5300 series user guide.Related topics• See “Meter resets”

Pagina 65 - Digital Alarms

PowerLogic™ PM5300 series user guide Chapter 6—Input / Output© 2014 Schneider Electric All Rights Reserved 49Chapter 6—Input / OutputThis section de

Pagina 66 - Alarm Setup

PowerLogic™ PM5300 series user guide Table of Contents© 2014 Schneider Electric All Rights Reserved5Chapter 1: Introduction Power and Energy Meter

Pagina 67 - Setting Up 1-Second Alarms

50 © 2014 Schneider Electric All Rights ReservedChapter 6—Input / Output PowerLogic™ PM5300 series user guideRelated topics• See “Technical Specifica

Pagina 68 - ▼ to select Select

PowerLogic™ PM5300 series user guide Chapter 6—Input / Output© 2014 Schneider Electric All Rights Reserved 51Configuring status inputs using the fro

Pagina 69 - ▼ to select Priority

52 © 2014 Schneider Electric All Rights ReservedChapter 6—Input / Output PowerLogic™ PM5300 series user guideDigital output applicationsDigital outpu

Pagina 70 - ▼ to select Dropout

PowerLogic™ PM5300 series user guide Chapter 6—Input / Output© 2014 Schneider Electric All Rights Reserved 53Configuring digital outputs using ION S

Pagina 71 - ▼ to select Enable

54 © 2014 Schneider Electric All Rights ReservedChapter 6—Input / Output PowerLogic™ PM5300 series user guideConfiguring digital outputs using the fr

Pagina 72

PowerLogic™ PM5300 series user guide Chapter 6—Input / Output© 2014 Schneider Electric All Rights Reserved 554. Move the cursor to point to the digi

Pagina 73

56 © 2014 Schneider Electric All Rights ReservedChapter 6—Input / Output PowerLogic™ PM5300 series user guideSelect Dmd System Power, CurrentApplies

Pagina 74

PowerLogic™ PM5300 series user guide Chapter 6—Input / Output© 2014 Schneider Electric All Rights Reserved 57Relay output applicationsRelay outputs

Pagina 75 - Chapter 8—Data Logs

58 © 2014 Schneider Electric All Rights ReservedChapter 6—Input / Output PowerLogic™ PM5300 series user guideBehavior Mode Normal, Timed, Coil Hold•

Pagina 76 - Alarm Log

PowerLogic™ PM5300 series user guide Chapter 6—Input / Output© 2014 Schneider Electric All Rights Reserved 59Configuring relay outputs using the fro

Pagina 77 - Power factor

PowerLogic™ PM5300 series user guide Table of Contents© 2014 Schneider Electric All Rights Reserved6Using ION Setup to view or modify configuration

Pagina 78 - Power factor sign convention

60 © 2014 Schneider Electric All Rights ReservedChapter 6—Input / Output PowerLogic™ PM5300 series user guideRelated topics• See “Demand setup” on pa

Pagina 79 - Block interval demand

PowerLogic™ PM5300 series user guide Chapter 6—Input / Output© 2014 Schneider Electric All Rights Reserved 61Configuring the LED or digital output f

Pagina 80 - Synchronized demand

62 © 2014 Schneider Electric All Rights ReservedChapter 6—Input / Output PowerLogic™ PM5300 series user guide4. Move the cursor to point to the param

Pagina 81 - Predicted demand

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved 63Chapter 7—AlarmsThis section describes the alar

Pagina 82 - 1:00 1:06 1:15

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved64• Dropout Setpoint (magnitude)• Dropout Time Del

Pagina 83 - Multi-tariff feature overview

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved 65Many of the 1-second alarms are three-phase ala

Pagina 84 - Time of day mode overview

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved66Unary AlarmsThe power meter has four unary alarm

Pagina 85

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved 67Setting Up 1-Second Alarms To set up a standard

Pagina 86 - Input mode overview

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved68Setting Up 1-Second Alarms (continued)NOTE: The

Pagina 87

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved 69Setting Up Unary Alarms To set up unary alarms:

Pagina 88

PowerLogic™ PM5300 series user guide Table of Contents© 2014 Schneider Electric All Rights Reserved7Chapter 12: Verifying accura-cyTesting overview

Pagina 89 - Chapter 11—Power quality

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved70Setting Up Digital AlarmsTo set up digital alarm

Pagina 90 - Displaying harmonics data

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved 71Setting Up Digital Alarms (continued)13. Press

Pagina 91 - Viewing TDD

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved72Viewing Alarm Activity and HistoryThere are two

Pagina 92

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved 73Viewing Unacknowledged Alarms and the Alarm His

Pagina 93 - Chapter 12—Verifying accuracy

PowerLogic™ PM5300 series user guide Chapter 7—Alarms© 2014 Schneider Electric All Rights Reserved74

Pagina 94 - Energy pulsing

PowerLogic™ PM5300 series user guide Chapter 8—Data Logs© 2014 Schneider Electric All Rights Reserved 75Chapter 8—Data LogsThis chapter briefly descr

Pagina 95

PowerLogic™ PM5300 series user guide Chapter 8—Data Logs© 2014 Schneider Electric All Rights Reserved76Memory Allocation for Log FilesEach file in th

Pagina 96 - Percent error calculation

PowerLogic™ PM5300 series user guide Chapter 9—Measurements and calculations© 2014 Schneider Electric All Rights Reserved 77Chapter 9—Measurements a

Pagina 97 - Energy pulsing considerations

78 © 2014 Schneider Electric All Rights ReservedChapter 9—Measurements and calculations PowerLogic™ PM5300 series user guidePower factor min/max conv

Pagina 98 - Test points

PowerLogic™ PM5300 series user guide Chapter 9—Measurements and calculations© 2014 Schneider Electric All Rights Reserved 79IEEE modeIn IEEE mode, t

Pagina 99 - Chapter 13—Meter resets

PowerLogic™ PM5300 series user guide Table of Contents© 2014 Schneider Electric All Rights Reserved8

Pagina 100 - Single resets

80 © 2014 Schneider Electric All Rights ReservedChapter 9—Measurements and calculations PowerLogic™ PM5300 series user guideThe following illustratio

Pagina 101

PowerLogic™ PM5300 series user guide Chapter 9—Measurements and calculations© 2014 Schneider Electric All Rights Reserved 81choose Cmd Sync Block (c

Pagina 102

82 © 2014 Schneider Electric All Rights ReservedChapter 9—Measurements and calculations PowerLogic™ PM5300 series user guidePeak demandThe maximum va

Pagina 103 - ▼ and ▲ to view

PowerLogic™ PM5300 series user guide Chapter 10—Multi-tariff feature© 2014 Schneider Electric All Rights Reserved 83Chapter 10—Multi-tariff featureT

Pagina 104 - ▲ to return to the

84 © 2014 Schneider Electric All Rights ReservedChapter 10—Multi-tariff feature PowerLogic™ PM5300 series user guideCommand mode overviewYou can use

Pagina 105 - Troubleshooting

PowerLogic™ PM5300 series user guide Chapter 10—Multi-tariff feature© 2014 Schneider Electric All Rights Reserved 85Tariff creation methodYour devic

Pagina 106 - Register List

86 © 2014 Schneider Electric All Rights ReservedChapter 10—Multi-tariff feature PowerLogic™ PM5300 series user guideAll days have a tariff applied be

Pagina 107 - Chapter 15—MID Compliance

PowerLogic™ PM5300 series user guide Chapter 10—Multi-tariff feature© 2014 Schneider Electric All Rights Reserved 87Configuring tariffs using the fr

Pagina 108 - Safety precautions

88 © 2014 Schneider Electric All Rights ReservedChapter 10—Multi-tariff feature PowerLogic™ PM5300 series user guide7. Modify each parameter as requi

Pagina 109 - PM5331/PM5341 default screen

PowerLogic™ PM5300 series user guide Chapter 11—Power quality© 2014 Schneider Electric All Rights Reserved 89Chapter 11—Power qualityThis section de

Pagina 110 - Lock-protected functions

PowerLogic™ PM5300 user guide Chapter 1—Introduction© 2014 Schneider Electric All Rights Reserved9Chapter 1—IntroductionThis user guide explains how

Pagina 111 - Initializing the meter

90 © 2014 Schneider Electric All Rights ReservedChapter 11—Power quality PowerLogic™ PM5300 series user guideTHD and thd calculationsThe meter suppor

Pagina 112 - Setting up lock password

PowerLogic™ PM5300 series user guide Chapter 11—Power quality© 2014 Schneider Electric All Rights Reserved 91The vertical axis of the harmonics grap

Pagina 113 - Glossary

92 © 2014 Schneider Electric All Rights ReservedChapter 11—Power quality PowerLogic™ PM5300 series user guideRelated topics• See “Front panel display

Pagina 114

PowerLogic™ PM5300 series user guide Chapter 12—Verifying accuracy© 2014 Schneider Electric All Rights Reserved 93Chapter 12—Verifying accuracyAll m

Pagina 115 - Abbreviations

94 © 2014 Schneider Electric All Rights ReservedChapter 12—Verifying accuracy PowerLogic™ PM5300 series user guideA warm-up time of 30 minutes is rec

Pagina 116

PowerLogic™ PM5300 series user guide Chapter 12—Verifying accuracy© 2014 Schneider Electric All Rights Reserved 95Verifying accuracy testThe followi

Pagina 117

96 © 2014 Schneider Electric All Rights ReservedChapter 12—Verifying accuracy PowerLogic™ PM5300 series user guide6. Depending on the method selected

Pagina 118

PowerLogic™ PM5300 series user guide Chapter 12—Verifying accuracy© 2014 Schneider Electric All Rights Reserved 97Where:• EM = energy measured by th

Pagina 119

98 © 2014 Schneider Electric All Rights ReservedChapter 12—Verifying accuracy PowerLogic™ PM5300 series user guideTest pointsThe meter should be test

Pagina 120

PowerLogic™ PM5300 series user guide Chapter 13—Meter resets© 2014 Schneider Electric All Rights Reserved 99Chapter 13—Meter resetsReset commands cl

Comentarios a estos manuales

Sin comentarios